5KV HV Relay GHR-46A/B/C
Home Products Vacuum RelayVacuum Relay (HV Relay)5KV HV Relay GHR-46A/B/C
5KV HV Relay GHR-46A/B/C
◆ Compact, space-saving design
◆ Vacuum dielectric for power switching low current loads.
◆ Widely used in antenna coupler applications
◆ Short actuator, low profile, 5kV relay
|
Product Specification
|
Units |
GHR46A |
GHR46B |
GHR46C |
||
|
Contact Form |
A |
B |
C |
|||
|
Contact Arrangement |
SPST-NO |
SPST-NC |
SPDT |
|||
|
Test Voltage,(kV, Peak), Test Max., Contacts & to Base (15 μA Leakage Max., dc or 60Hz) |
KV Peak |
6 |
6 |
6 |
||
|
Rated Operating Voltage, (kV,Peak), Contacts & to Base (15 μA Leakage Max.) |
DC or 60Hz |
KV Peak |
5 |
5 |
5 |
|
|
2.5MHz |
KV Peak |
4.5 |
4.5 |
4.5 |
||
|
16MHz |
KV Peak |
3.5 |
3.5 |
3.5 |
||
|
32MHz |
KV Peak |
2.8 |
2.8 |
2.8 |
||
|
Continuous Current, Carry Max |
DC or 60Hz |
Amps |
12 |
12 |
12 |
|
|
2.5MHz |
Amps |
10 |
10 |
10 |
||
|
16MHz |
Amps |
5 |
5 |
5 |
||
|
32MHz |
Amps |
3 |
3 |
3 |
||
|
Coil Hi -Pot (V RMS, 60 Hz) |
V |
500 |
500 |
500 |
||
|
Capacitance |
Across Open Contacts |
pF |
1.6 |
1.6 |
1.6 |
|
|
Contacts to Ground |
pF |
2 |
2 |
2 |
||
|
Resistance, Contact Max @ 1A, 28Vdc |
Ω |
0.05 |
0.05 |
0.05 |
||
|
Operate Time, Max |
ms |
10 |
10 |
10 |
||
|
Release Time, Max |
ms |
10 |
10 |
10 |
||
|
Operating Temperature Ambient |
°C |
-55~ 125 |
-55~ 125 |
-55~ 125 |
||
|
Shock, 1/2 Sine11ms (Peak) |
G’s |
50 |
50 |
50 |
||
|
Vibration, Sine (10-2000 Hz Peak) |
G’s |
10 |
10 |
10 |
||
|
Mechanical Life |
Cycles |
2 million |
2 million |
2 million |
||
|
Weight |
g |
22 |
22 |
22 |
||
|
Nominal,Volts dc |
12 |
26.5 |
115 |
|
Pick-up,Volts dc,Max |
8 |
16 |
80 |
|
Drop-Out,Volts dc,Min |
0.5-5 |
1-10 |
5-50 |
|
Coil Resistance(Ω±10%) |
70 |
290 |
4700 |
|
※ Ratings listed are for 25°C |
|||
|
GHR46 |
Design code |
|
|
A |
Contact form |
A: SPST-NO |
|
B: SPST-NC |
||
|
C: SPDT |
||
|
3 |
Coil voltage |
2 - 12Vdc bus wire |
|
3 - 26.5Vdc bus wire |
||
|
5 - 115Vdc bus wire |
||
|
7 - 12Vdc turret terminal |
||
|
8 - 26.5Vdc turret terminal |
||
|
9 - 115Vdc turret terminal |
||
|
3 |
HV connection method |
3 - Solder connection |
|
4 |
Mounting method |
2 - Flanged |
|
4 - Standard |